Library: l_sm3_driveutil.lib, Function block l_smc_settorquelimit (for ethercat), L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 28

Advertising
background image

L-force | PLC Designer

Lenze Specific Functions

26

DMS 4.1 EN 03/2011 TD29

Error messages from the function block

Error number

Meaning

507

Incorrect format indicated during an instance of write access

531

Incorrect format indicated during assignment

532

Code contains float/double parameters (e.g. supply voltage C00205 or
rechargeable-battery voltage C00207); This format is not supported by the
block.

Other

Internal software error; Please contact your Lenze Service Centre.

2.1.3

Library: L_SM3_DriveUtil.lib

Function block L_SMC_SetTorqueLimit (for EtherCAT)
Function library: L_SM3_DriveUtil.lib
The torque limits of a drive in the positive and negative direction of rotation can be
prescribed by the control system. Previously, the limits were set by means of SDO
access. If the drives are controlled via an EtherCAT fieldbus, it is possible to transfer
these values as part of the cyclical process data. The advantage of this is considerably
faster transfer of the values to the drive.In order to use this, a corresponding mapping
that contains these torque limits as an item of process data must be selected in the
EtherCAT Configurator.
Access to the torque limits from the PLC takes place by means of the function block
L_SMC_SetTorqueLimit:


Inputs (VAR_IN)

Designator / Data type

Info / Setting options

Execute / BOOL

Activates the function.

SetTorqueLimitPos / BOOL Requests a positive torque limit

TorqueLimitPos_Value /
LREAL

Positive torque limit in the range 0 ... 100 % of the rated torque

SetTorqueLimitNeg / BOOL Requests a negative torque limit

TorqueLimitNeg_Value /
LREAL

Negative torque limit in the range 0 ... 100 % of the rated torque

Axis / AXIS_REF

Here, the axis structure to which these torque limits apply is transferred.