L-force | PLC Designer

Lenze Specific Functions

40

DMS 4.1 EN 03/2011 TD29

Error messages
The following error messages have been stored:

Error message

Description

411

TouchProbeSelect incorrect: TP channel does not exist
TouchProbeSelect > 1 in the case of ECSxM
TouchProbeSelect > 2 in the case of 9400

412

TouchProbeMode incorrect: Only the values 1 or 2 are permitted.

413

TouchProbeEdge incorrect: Only the values 1, 2 or 3 are permitted.

414

TouchProbeEdge incorrect: Requested edge evaluation does not exist
TouchProbeEdge > 2 in the case of ECSxM (Only positive or negative edge
possible.)
TouchProbeEdge > 4 in the case of 9400 (Type of edge evaluated not
supported.)

415

TP channel not free:
TP channel has already been activated by means of other block.

416

Touch probe is not possible for the currently selected process data
mapping.

417

Internal error / TP channel not free:
TP channel has already been activated by means of other block.

418

Internal error:
Timeout during assignment of the drive

419

Internal error: Communication error

421

TouchProbeSignal incorrect: Only the value 1 is permitted.

430

The FreeEncoder axis specified at the Axis input does not exist

431

The FreeEncoder axis specified at the Axis input is configured incorrectly

432

TouchProbeEdge selection incorrect

433

TouchProbeEdge selection incorrect