L-force | PLC Designer

Device Editors

856

DMS 4.1 EN 03/2011 TD29

When an application gets loaded to the PLC, it will be checked whether the list of
applications on the PLC matches the list of applications in the devices tree and also
whether the parameters of an application on the PLC match the parameters of the
application in the device configuration ("signatures"). If inconsistencies are detected,
an appropriate message ("unresolved reference(s)" resp. "signature mismatch(es)") will
be generated in a message box as well as in the message view in category "Download".

Abb. 470 Message about unresolved references, example

If multiple applications are directly assigned to the device notice the actual setting
concerning I/O mapping.
See also Application for general information on handling application projects.

Files
This dialog is provided on a tab of the Device dialog (Device Editor), which can be
opened for the device currently selected in the devices tree via command 'Edit Object'
or by a double-click on the device entry in the Devices window.
The dialog serves to transfer files between the host and the controller. This means you
can choose any file from a directory of the local network to get it copied to the files
directory of the currently connected runtime system, or the other way round.

Abb. 471 Device dialog, Files